TROUBLESHOOTING
| Code | Causes | Resolutions |
|
E01 |
Communication error |
1. Check whether the electric display is properly connected to the controller.
2. Reinsert the main IC of the controller as it is in poor contact. 3. Replace the controller as its power supply is abnormal. |
|
E02 |
Explosion protection |
1. Replace the motor or check the connection terminal as motor open circuit or contact fails.
2. Replace the power tube or controller as power tube is damaged. |
| E05 | Overcurrent protection | 1. Overload
2. Add lubricating oil as the resistance on the running belt is high. 3. Replace damaged motor. |
| E06 | Overload protection | |
| E10 | Failure in communication between keyboard and control panel. | 1. Check whether the electric display is properly connected to the controller.
2. Reinsert the plug of the controller as it is in poor contact. 3. Replace the controller as its power supply is abnormal. |
https://manuals.plus/urevo/ur9tm0011-2-in-1-under-desk-treadmill-manual#ixzz7r6z3pG2P